Juniper SRX Cluster Failover Tuning

If you check Juniper configuration guide for SRX firewall clustering, there will be a default example of redundancy-group weight values which are fine if you have one Uplink towards outside and multiple inside interfaces on that firewall.
set chassis cluster redundancy-group 0 node 0 priority 100 set chassis cluster redundancy-group 0 node 1 priority 1 set chassis cluster redundancy-group 1 node 0 priority 100 set chassis cluster redundancy-group 1 node 1 priority 1 set chassis cluster redundancy-group 1 interface-monitor ge-0/0/5 weight 255 set chassis cluster redundancy-group 1 interface-monitor ge-0/0/4 weight 255 set chassis cluster redundancy-group 1 interface-monitor ge-5/0/5 weight 255 set chassis cluster redundancy-group 1 interface-monitor ge-5/0/4 weight 255
This is the one: https://www.juniper.net/documentation/en_US/junos/topics/topic-map/security-chassis-cluster-verification.html
But if!
If you get to a situation where you may have multiple outside interfaces which are giving you Internet access or WAN access redundancy then maybe you don’t want failover to secondary SRX box to occur when you lose one of those two uplinks. If that’s the case, you should follow this article and get your SRX cluster to behave as it should.






Multinational publicly registered IT Company, “Juniper Networks” and its logo both are the listed trademarks of the Juniper Networks, Inc. which is today’s leader in their performance relating networking. Company was established in the year of 1996 by Mr. Pradeep Sindhu. But at the moment, Juniper’s headquarter is situated in the California with lots branches in the different areas of the world.